Review measurement

2025-08-28 15:07

Ozone Delta 5 L (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7542
rdg:
7537
diff:
 -5
A2a
nom:
7465
rdg:
7458
diff:
 -7
A3a
nom:
7423
rdg:
7414
diff:
 -9
A4a
nom:
7447
rdg:
7441
diff:
 -6
A1b
nom:
7528
rdg:
7530
diff:
 +2
A2b
nom:
7449
rdg:
7444
diff:
 -5
A3b
nom:
7409
rdg:
7403
diff:
 -6
A4b
nom:
7436
rdg:
7429
diff:
 -7
B7
nom:
7356
rdg:
7353
diff:
 -3
B8
nom:
7250
rdg:
7256
diff:
 +6
B9
nom:
7226
rdg:
7231
diff:
 +5
B10
nom:
7156
rdg:
7163
diff:
 +7
B11
nom:
7137
rdg:
7137
diff:
 +0
B12
nom:
7149
rdg:
7149
diff:
 +0
C7
nom:
7451
rdg:
7454
diff:
 +3
C8
nom:
7341
rdg:
7344
diff:
 +3
C9
nom:
7314
rdg:
7315
diff:
 +1
C10
nom:
7236
rdg:
7242
diff:
 +6
C11
nom:
7215
rdg:
7216
diff:
 +1
C12
nom:
7207
rdg:
7210
diff:
 +3
B13
nom:
7020
rdg:
7012
diff:
 -8
B14
nom:
6926
rdg:
6915
diff:
-11
B15
nom:
6873
rdg:
6863
diff:
-10
B16
nom:
6858
rdg:
6848
diff:
-10

Right riser

A1a
nom:
7542
rdg:
7541
diff:
 -1
A2a
nom:
7465
rdg:
7459
diff:
 -6
A3a
nom:
7423
rdg:
7420
diff:
 -3
A4a
nom:
7447
rdg:
7445
diff:
 -2
A1b
nom:
7528
rdg:
7527
diff:
 -1
A2b
nom:
7449
rdg:
7446
diff:
 -3
A3b
nom:
7409
rdg:
7404
diff:
 -5
A4b
nom:
7436
rdg:
7435
diff:
 -1
B7
nom:
7356
rdg:
7357
diff:
 +1
B8
nom:
7250
rdg:
7254
diff:
 +4
B9
nom:
7226
rdg:
7231
diff:
 +5
B10
nom:
7156
rdg:
7158
diff:
 +2
B11
nom:
7137
rdg:
7140
diff:
 +3
B12
nom:
7149
rdg:
7148
diff:
 -1
C7
nom:
7451
rdg:
7446
diff:
 -5
C8
nom:
7341
rdg:
7348
diff:
 +7
C9
nom:
7314
rdg:
7315
diff:
 +1
C10
nom:
7236
rdg:
7236
diff:
 +0
C11
nom:
7215
rdg:
7215
diff:
 +0
C12
nom:
7207
rdg:
7207
diff:
 +0
B13
nom:
7020
rdg:
6998
diff:
-22
B14
nom:
6926
rdg:
6913
diff:
-13
B15
nom:
6873
rdg:
6863
diff:
-10
B16
nom:
6858
rdg:
6843
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee