Review measurement
2024-11-18 11:49
PHI Maestro 2 Light 18 (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom: 7192.75
rdg: 7154.75
diff: -38.00
nom: 7154.75
rdg: 7107.00
diff: -47.75
nom: 7241.38
rdg: 7204.88
diff: -36.50
nom: 7115.00
rdg: 7075.25
diff: -39.75
nom: 7086.25
rdg: 7042.25
diff: -44.00
nom: 7184.13
rdg: 7153.88
diff: -30.25
nom: 6924.17
rdg: 6888.00
diff: -36.17
nom: 6874.50
rdg: 6834.17
diff: -40.33
nom: 6903.17
rdg: 6873.50
diff: -29.67
Right riser
nom: 7115.00
rdg: 7073.00
diff: -42.00
nom: 7086.25
rdg: 7042.25
diff: -44.00
nom: 7184.13
rdg: 7151.75
diff: -32.38
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found