Review measurement

2023-07-24 17:26

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7232
diff:
-6
A10
nom:
7112
rdg:
7103
diff:
-9
A11
nom:
7043
rdg:
7038
diff:
-5
A12
nom:
6996
rdg:
6983
diff:
-13
A13
nom:
6976
rdg:
6963
diff:
-13
A14
nom:
7018
rdg:
6998
diff:
-20
B12
nom:
7005
rdg:
6986
diff:
-19
B13
nom:
7013
rdg:
6996
diff:
-17
B14
nom:
7041
rdg:
7019
diff:
-22

Right riser

A9
nom:
7238
rdg:
7231
diff:
-7
A10
nom:
7112
rdg:
7104
diff:
-8
A11
nom:
7043
rdg:
7036
diff:
-7
A12
nom:
6996
rdg:
6986
diff:
-10
A13
nom:
6976
rdg:
6966
diff:
-10
A14
nom:
7018
rdg:
7006
diff:
-12
B12
nom:
7005
rdg:
6992
diff:
-13
B13
nom:
7013
rdg:
7001
diff:
-12
B14
nom:
7041
rdg:
7026
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found