Review measurement

2025-04-21 08:54

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
8099
rdg:
8095
diff:
 -4
A6a
nom:
7952
rdg:
7946
diff:
 -6
A7a
nom:
7881
rdg:
7876
diff:
 -5
A8a
nom:
7909
rdg:
7903
diff:
 -6
A5b
nom:
8082
rdg:
8083
diff:
 +1
A6b
nom:
7936
rdg:
7933
diff:
 -3
A7b
nom:
7866
rdg:
7863
diff:
 -3
A8b
nom:
7897
rdg:
7893
diff:
 -4

Right riser

A5a
nom:
8099
rdg:
8098
diff:
 -1
A6a
nom:
7952
rdg:
7946
diff:
 -6
A7a
nom:
7881
rdg:
7876
diff:
 -5
A8a
nom:
7909
rdg:
7900
diff:
 -9
A5b
nom:
8082
rdg:
8083
diff:
 +1
A6b
nom:
7936
rdg:
7932
diff:
 -4
A7b
nom:
7866
rdg:
7863
diff:
 -3
A8b
nom:
7897
rdg:
7887
diff:
-10

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

Right riser

nom:
n/a
rdg:
8215.88
diff:
-2.25
nom:
n/a
rdg:
8199.50
diff:
8.50

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found