Review measurement

2026-09-22 16:30

Niviuk Ikuma 2 P 24 (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a13
nom:
6476
rdg:
6305
diff:
-171
a14
nom:
6406
rdg:
6232
diff:
-174
b13
nom:
6452
rdg:
6281
diff:
-171
b14
nom:
6404
rdg:
6235
diff:
-169
c13
nom:
6469
rdg:
6286
diff:
-183

Right riser

a13
nom:
6476
rdg:
6294
diff:
-182
a14
nom:
6406
rdg:
6221
diff:
-185
b13
nom:
6452
rdg:
6275
diff:
-177
b14
nom:
6404
rdg:
6222
diff:
-182
c13
nom:
6469
rdg:
6276
diff:
-193

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6822.75
rdg:
6621.00
diff:
-201.75
nom:
6760.50
rdg:
6571.50
diff:
-189.00
nom:
6826.75
rdg:
6640.75
diff:
-186.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-188) of the deviations of all measurements from their nominal values.

No issues were found