Review measurement

2026-03-20 18:53

Ozone Photon MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7258
rdg:
7257
diff:
 -1
A2a
nom:
7157
rdg:
7145
diff:
-12
A3a
nom:
7121
rdg:
7105
diff:
-16
A4a
nom:
7153
rdg:
7137
diff:
-16
A1b
nom:
7243
rdg:
7229
diff:
-14
A2b
nom:
7141
rdg:
7125
diff:
-16
A3b
nom:
7107
rdg:
7092
diff:
-15
A4b
nom:
7140
rdg:
7123
diff:
-17

Right riser

A1a
nom:
7258
rdg:
7248
diff:
-10
A2a
nom:
7157
rdg:
7141
diff:
-16
A3a
nom:
7121
rdg:
7103
diff:
-18
A4a
nom:
7153
rdg:
7138
diff:
-15
A1b
nom:
7243
rdg:
7233
diff:
-10
A2b
nom:
7141
rdg:
7127
diff:
-14
A3b
nom:
7107
rdg:
7091
diff:
-16
A4b
nom:
7140
rdg:
7125
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6592.33
rdg:
6573.67
diff:
-18.67
nom:
6601.33
rdg:
6593.33
diff:
-8.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found