Review measurement

2026-05-19 09:23

Ozone Zeolite 2 S (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6585
rdg:
6571
diff:
-14
A10
nom:
6463
rdg:
6457
diff:
 -6
A11
nom:
6397
rdg:
6390
diff:
 -7
A12
nom:
6307
rdg:
6298
diff:
 -9
A13
nom:
6288
rdg:
6270
diff:
-18
B12
nom:
6327
rdg:
6319
diff:
 -8
B13
nom:
6310
rdg:
6295
diff:
-15

Right riser

A9
nom:
6585
rdg:
6573
diff:
-12
A10
nom:
6463
rdg:
6459
diff:
 -4
A11
nom:
6397
rdg:
6391
diff:
 -6
A12
nom:
6307
rdg:
6299
diff:
 -8
A13
nom:
6288
rdg:
6274
diff:
-14
B12
nom:
6327
rdg:
6314
diff:
-13
B13
nom:
6310
rdg:
6290
diff:
-20

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6481.67
rdg:
6474.33
diff:
-7.33
nom:
6500.67
rdg:
6482.67
diff:
-18.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found