Review measurement

2026-05-19 09:23

Ozone Zeolite 2 S (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6585
rdg:
6571
diff:
-14
A10
nom:
6463
rdg:
6457
diff:
 -6
A11
nom:
6397
rdg:
6390
diff:
 -7
A12
nom:
6307
rdg:
6298
diff:
 -9
A13
nom:
6288
rdg:
6270
diff:
-18
B12
nom:
6327
rdg:
6319
diff:
 -8
B13
nom:
6310
rdg:
6295
diff:
-15

Right riser

A9
nom:
6585
rdg:
6573
diff:
-12
A10
nom:
6463
rdg:
6459
diff:
 -4
A11
nom:
6397
rdg:
6391
diff:
 -6
A12
nom:
6307
rdg:
6299
diff:
 -8
A13
nom:
6288
rdg:
6274
diff:
-14
B12
nom:
6327
rdg:
6314
diff:
-13
B13
nom:
6310
rdg:
6290
diff:
-20

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6481.67
rdg:
6474.33
diff:
-7.33
nom:
6500.67
rdg:
6482.67
diff:
-18.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-26) of the deviations of all measurements from their nominal values.

No issues were found