Review measurement

2025-11-07 11:45

Niviuk Artik R 2 21 (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
6612
rdg:
6606
diff:
 -6
a10
nom:
6486
rdg:
6478
diff:
 -8
a11
nom:
6403
rdg:
6396
diff:
 -7
a12
nom:
6393
rdg:
6384
diff:
 -9
a13
nom:
6250
rdg:
6386
diff:
+136
a14
nom:
6228
rdg:
6368
diff:
+140
c13
nom:
6260
rdg:
6398
diff:
+138
c14
nom:
6265
rdg:
6403
diff:
+138
c1
nom:
6813
rdg:
6823
diff:
+10
c2
nom:
6780
rdg:
6790
diff:
+10
c3
nom:
6762
rdg:
6765
diff:
 +3
c4
nom:
6782
rdg:
6788
diff:
 +6
d1
nom:
6944
rdg:
6943
diff:
 -1
d2
nom:
6915
rdg:
6915
diff:
 +0
d3
nom:
6895
rdg:
6895
diff:
 +0
d4
nom:
6908
rdg:
6909
diff:
 +1
c5
nom:
6733
rdg:
6741
diff:
 +8
c6
nom:
6700
rdg:
6711
diff:
+11
c7
nom:
6656
rdg:
6663
diff:
 +7
c8
nom:
6663
rdg:
6670
diff:
 +7
d5
nom:
6860
rdg:
6858
diff:
 -2
d6
nom:
6826
rdg:
6829
diff:
 +3
d7
nom:
6774
rdg:
6775
diff:
 +1
d8
nom:
6773
rdg:
6777
diff:
 +4

Right riser

a9
nom:
6612
rdg:
6605
diff:
 -7
a10
nom:
6486
rdg:
6477
diff:
 -9
a11
nom:
6403
rdg:
6392
diff:
-11
a12
nom:
6393
rdg:
6386
diff:
 -7
a13
nom:
6250
rdg:
6387
diff:
+137
a14
nom:
6228
rdg:
6368
diff:
+140
c13
nom:
6260
rdg:
6400
diff:
+140
c14
nom:
6265
rdg:
6400
diff:
+135
c1
nom:
6813
rdg:
6826
diff:
+13
c2
nom:
6780
rdg:
6794
diff:
+14
c3
nom:
6762
rdg:
6763
diff:
 +1
c4
nom:
6782
rdg:
6783
diff:
 +1
d1
nom:
6944
rdg:
6946
diff:
 +2
d2
nom:
6915
rdg:
6918
diff:
 +3
d3
nom:
6895
rdg:
6891
diff:
 -4
d4
nom:
6908
rdg:
6905
diff:
 -3
c5
nom:
6733
rdg:
6739
diff:
 +6
c6
nom:
6700
rdg:
6712
diff:
+12
c7
nom:
6656
rdg:
6657
diff:
 +1
c8
nom:
6663
rdg:
6663
diff:
 +0
d5
nom:
6860
rdg:
6855
diff:
 -5
d6
nom:
6826
rdg:
6824
diff:
 -2
d7
nom:
6774
rdg:
6772
diff:
 -2
d8
nom:
6773
rdg:
6772
diff:
 -1

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
6473.50
rdg:
6466.00
diff:
-10.50

Right riser

nom:
6473.50
rdg:
6465.00
diff:
-11.50

Buy us coffee