Review measurement

2025-08-02 11:35

Niviuk Ikuma 3P 24 (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a5
nom:
7025
rdg:
7002
diff:
-23
a6
nom:
6986
rdg:
6962
diff:
-24
a7
nom:
6919
rdg:
6895
diff:
-24
a8
nom:
6927
rdg:
6914
diff:
-13
b9
nom:
6784
rdg:
6745
diff:
-39
b10
nom:
6694
rdg:
6664
diff:
-30
b11
nom:
6610
rdg:
6574
diff:
-36
b12
nom:
6597
rdg:
6557
diff:
-40
c9
nom:
6847
rdg:
6800
diff:
-47
c10
nom:
6758
rdg:
6717
diff:
-41
c11
nom:
6660
rdg:
6622
diff:
-38
c12
nom:
6646
rdg:
6608
diff:
-38
c5
nom:
7046
rdg:
7016
diff:
-30
c6
nom:
6995
rdg:
6972
diff:
-23
c7
nom:
6933
rdg:
6902
diff:
-31
c8
nom:
6958
rdg:
6924
diff:
-34
d5
nom:
7120
rdg:
7098
diff:
-22
d6
nom:
7068
rdg:
7043
diff:
-25
d7
nom:
6999
rdg:
6978
diff:
-21
d8
nom:
7004
rdg:
6974
diff:
-30

Right riser

a5
nom:
7025
rdg:
7007
diff:
-18
a6
nom:
6986
rdg:
6964
diff:
-22
a7
nom:
6919
rdg:
6905
diff:
-14
a8
nom:
6927
rdg:
6904
diff:
-23
b9
nom:
6784
rdg:
6747
diff:
-37
b10
nom:
6694
rdg:
6657
diff:
-37
b11
nom:
6610
rdg:
6578
diff:
-32
b12
nom:
6597
rdg:
6555
diff:
-42
c9
nom:
6847
rdg:
6809
diff:
-38
c10
nom:
6758
rdg:
6721
diff:
-37
c11
nom:
6660
rdg:
6619
diff:
-41
c12
nom:
6646
rdg:
6606
diff:
-40
c5
nom:
7046
rdg:
7022
diff:
-24
c6
nom:
6995
rdg:
6974
diff:
-21
c7
nom:
6933
rdg:
6912
diff:
-21
c8
nom:
6958
rdg:
6936
diff:
-22
d5
nom:
7120
rdg:
7104
diff:
-16
d6
nom:
7068
rdg:
7048
diff:
-20
d7
nom:
6999
rdg:
6975
diff:
-24
d8
nom:
7004
rdg:
6976
diff:
-28

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7138.25
rdg:
7121.75
diff:
-16.50
nom:
7044.50
rdg:
7009.75
diff:
-34.75
nom:
7178.25
rdg:
7149.00
diff:
-29.25
nom:
6671.25
rdg:
6649.50
diff:
-21.75
nom:
6699.50
rdg:
6660.88
diff:
-38.63

Right riser

nom:
6671.25
rdg:
6646.25
diff:
-25.00
nom:
6699.50
rdg:
6661.50
diff:
-38.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee