Review measurement
2025-08-18 15:17
Ozone Rush 6 ML (2021)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B9
nom:
6989
rdg:
7066
diff:
+77
B10
nom:
6927
rdg:
7006
diff:
+79
B11
nom:
6846
rdg:
6927
diff:
+81
B12
nom:
6832
rdg:
6913
diff:
+81
B13
nom:
6736
rdg:
6816
diff:
+80
B14
nom:
6741
rdg:
6823
diff:
+82
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
7329.25
rdg:
7396.50
diff:
67.25
nom:
7249.25
rdg:
7319.25
diff:
70.00
nom:
7443.00
rdg:
7521.63
diff:
78.63
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found