Review measurement

2026-06-10 14:56

Ozone Zeno ML (2017)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
5.38
std dev:
3.93
A1a
dev:
-1.6
A2a
dev:
+1.4
A3a
dev:
+3.4
A4a
dev:
+2.4
A1b
dev:
+5.4
A2b
dev:
-3.6
A3b
dev:
-0.6
A4b
dev:
-6.6
avg change:
6.00
std dev:
1.73
B9
dev:
+1.0
B10
dev:
-2.0
B11
dev:
+1.0

Right riser

avg change:
12.25
std dev:
1.58
A1a
dev:
+1.3
A2a
dev:
-0.8
A3a
dev:
-0.8
A4a
dev:
+1.3
A1b
dev:
+0.3
A2b
dev:
-0.8
A3b
dev:
-2.8
A4b
dev:
+2.3
avg change:
16.88
std dev:
1.36
A5a
dev:
+0.9
A6a
dev:
-1.1
A7a
dev:
+1.9
A8a
dev:
-1.1
A5b
dev:
-0.1
A6b
dev:
+0.9
A7b
dev:
-2.1
A8b
dev:
+0.9
avg change:
13.50
std dev:
1.51
B1
dev:
-1.5
B2
dev:
+1.5
B3
dev:
-1.5
B4
dev:
-0.5
C1
dev:
+0.5
C2
dev:
+0.5
C3
dev:
+2.5
C4
dev:
-1.5
avg change:
9.88
std dev:
2.85
B5
dev:
+1.1
B6
dev:
-0.9
B7
dev:
+0.1
B8
dev:
-4.9
C5
dev:
-1.9
C6
dev:
+0.1
C7
dev:
+1.1
C8
dev:
+5.1
avg change:
15.00
std dev:
2.65
B9
dev:
+2.0
B10
dev:
-3.0
B11
dev:
+1.0

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6786
rdg:
7281
diff:
-25
A10
nom:
6663
rdg:
7161
diff:
-22
A11
nom:
6602
rdg:
7093
diff:
-29
A12
nom:
6548
rdg:
7030
diff:
-38
A13
nom:
6531
rdg:
7014
diff:
-37
A14
nom:
6563
rdg:
7050
diff:
-33
B12
nom:
6556
rdg:
7041
diff:
-35
B13
nom:
6562
rdg:
7050
diff:
-32
B14
nom:
6587
rdg:
7074
diff:
-33

Right riser

A9
nom:
6786
rdg:
7284
diff:
-22
A10
nom:
6663
rdg:
7161
diff:
-22
A11
nom:
6602
rdg:
7096
diff:
-26
A12
nom:
6548
rdg:
7037
diff:
-31
A13
nom:
6531
rdg:
7021
diff:
-30
A14
nom:
6563
rdg:
7056
diff:
-27
B12
nom:
6556
rdg:
7045
diff:
-31
B13
nom:
6562
rdg:
7048
diff:
-34
B14
nom:
6587
rdg:
7078
diff:
-29

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7601.13
rdg:
7572.88
diff:
-28.25
nom:
7581.38
rdg:
7577.13
diff:
-4.25

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-23) of the deviations of all measurements from their nominal values.

No issues were found