Review measurement

2026-08-15 11:02

Ozone Zeolite 2 MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7221
rdg:
7209
diff:
-12
A6a
nom:
7081
rdg:
7068
diff:
-13
A7a
nom:
7010
rdg:
6996
diff:
-14
A8a
nom:
7023
rdg:
7009
diff:
-14
A5b
nom:
7212
rdg:
7209
diff:
 -3
A6b
nom:
7073
rdg:
7063
diff:
-10
A7b
nom:
7004
rdg:
6994
diff:
-10
A8b
nom:
7020
rdg:
7002
diff:
-18

Right riser

A5a
nom:
7221
rdg:
7204
diff:
-17
A6a
nom:
7081
rdg:
7063
diff:
-18
A7a
nom:
7010
rdg:
6993
diff:
-17
A8a
nom:
7023
rdg:
7004
diff:
-19
A5b
nom:
7212
rdg:
7199
diff:
-13
A6b
nom:
7073
rdg:
7057
diff:
-16
A7b
nom:
7004
rdg:
6988
diff:
-16
A8b
nom:
7020
rdg:
7004
diff:
-16

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-14) of the deviations of all measurements from their nominal values.

No issues were found