Review measurement

2025-06-13 16:17

Ozone Enzo 3 L (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B17
nom:
7990
rdg:
7996
diff:
 +6
B18
nom:
7924
rdg:
7932
diff:
 +8
B19
nom:
7904
rdg:
7909
diff:
 +5
B20
nom:
7827
rdg:
7835
diff:
 +8
B21
nom:
7831
rdg:
7835
diff:
 +4
B22
nom:
7784
rdg:
7786
diff:
 +2
B23
nom:
7792
rdg:
7792
diff:
 +0

Right riser

B17
nom:
7990
rdg:
7998
diff:
 +8
B18
nom:
7924
rdg:
7926
diff:
 +2
B19
nom:
7904
rdg:
7903
diff:
 -1
B20
nom:
7827
rdg:
7826
diff:
 -1
B21
nom:
7831
rdg:
7831
diff:
 +0
B22
nom:
7784
rdg:
7784
diff:
 +0
B23
nom:
7792
rdg:
7785
diff:
 -7

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
8524.00
rdg:
8531.00
diff:
7.00
nom:
8496.88
rdg:
8516.63
diff:
19.75

Right riser

nom:
8524.00
rdg:
8531.25
diff:
7.25
nom:
8496.88
rdg:
8514.38
diff:
17.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7601.25
rdg:
7586.25
diff:
-21.00

Right riser

nom:
7601.25
rdg:
7583.00
diff:
-24.25

Buy us coffee