Review measurement

2026-07-05 12:35

Flow Cosmos M (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c5
nom:
7052
rdg:
6981
diff:
-537
c6
nom:
7033
rdg:
6967
diff:
-532
c7
nom:
7015
rdg:
6947
diff:
-534
c8
nom:
7020
rdg:
6956
diff:
-530
d5
nom:
7172
rdg:
7118
diff:
-520
d6
nom:
7155
rdg:
7096
diff:
-525
d7
nom:
7131
rdg:
7053
diff:
-544
d8
nom:
7118
rdg:
7071
diff:
-513
b9
nom:
6876
rdg:
6817
diff:
-525
b10
nom:
6841
rdg:
6782
diff:
-525
b11
nom:
6764
rdg:
6694
diff:
-536
b12
nom:
6713
rdg:
6641
diff:
-538
b13
nom:
6709
rdg:
6640
diff:
-535

Right riser

c5
nom:
7052
rdg:
6981
diff:
-537
c6
nom:
7033
rdg:
6967
diff:
-532
c7
nom:
7015
rdg:
6947
diff:
-534
c8
nom:
7020
rdg:
6956
diff:
-530
d5
nom:
7172
rdg:
7118
diff:
-520
d6
nom:
7155
rdg:
7096
diff:
-525
d7
nom:
7131
rdg:
7053
diff:
-544
d8
nom:
7118
rdg:
7071
diff:
-513
b9
nom:
6876
rdg:
6817
diff:
-525
b10
nom:
6841
rdg:
6782
diff:
-525
b11
nom:
6764
rdg:
6694
diff:
-536
b12
nom:
6713
rdg:
6641
diff:
-538
b13
nom:
6709
rdg:
6640
diff:
-535

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-534) of the deviations of all measurements from their nominal values.

No issues were found