Review measurement

2024-12-02 21:22

Ozone Enzo 3 S (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7387
rdg:
7397
diff:
+10
A10
nom:
7341
rdg:
7351
diff:
+10
A11
nom:
7256
rdg:
7271
diff:
+15
A12
nom:
7254
rdg:
7268
diff:
+14
A13
nom:
7195
rdg:
7201
diff:
+6
A14
nom:
7202
rdg:
7206
diff:
+4

Right riser

A9
nom:
7387
rdg:
7390
diff:
+3
A10
nom:
7341
rdg:
7346
diff:
+5
A11
nom:
7256
rdg:
7265
diff:
+9
A12
nom:
7254
rdg:
7262
diff:
+8
A13
nom:
7195
rdg:
7196
diff:
+1
A14
nom:
7202
rdg:
7204
diff:
+2

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found