Review measurement
2025-08-02 17:25
Ozone Zeolite GT S (2019)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B9
nom:
6301
rdg:
6846
diff:
+25
B10
nom:
6252
rdg:
6799
diff:
+27
B11
nom:
6167
rdg:
6708
diff:
+21
B12
nom:
6163
rdg:
6705
diff:
+22
B13
nom:
6121
rdg:
6658
diff:
+17
B14
nom:
6112
rdg:
6651
diff:
+19
Right riser
A15
nom:
5889
rdg:
6436
diff:
+22
A16
nom:
5839
rdg:
6381
diff:
+17
A17
nom:
5835
rdg:
6368
diff:
+8
B15
nom:
5913
rdg:
6459
diff:
+21
B16
nom:
5887
rdg:
6423
diff:
+11
B17
nom:
5877
rdg:
6400
diff:
-2
B9
nom:
6301
rdg:
6851
diff:
+30
B10
nom:
6252
rdg:
6800
diff:
+28
B11
nom:
6167
rdg:
6712
diff:
+25
B12
nom:
6163
rdg:
6709
diff:
+26
B13
nom:
6121
rdg:
6659
diff:
+18
B14
nom:
6112
rdg:
6654
diff:
+22
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.