Review measurement

2026-06-22 11:43

Ozone Alpina 5 L (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B7
nom:
7356
rdg:
7366
diff:
+10
B8
nom:
7250
rdg:
7262
diff:
+12
B9
nom:
7226
rdg:
7236
diff:
+10
B10
nom:
7156
rdg:
7162
diff:
 +6
B11
nom:
7137
rdg:
7145
diff:
 +8
B12
nom:
7149
rdg:
7155
diff:
 +6
C7
nom:
7451
rdg:
7469
diff:
+18
C8
nom:
7341
rdg:
7360
diff:
+19
C9
nom:
7314
rdg:
7332
diff:
+18
C10
nom:
7236
rdg:
7251
diff:
+15
C11
nom:
7215
rdg:
7229
diff:
+14
C12
nom:
7207
rdg:
7220
diff:
+13

Right riser

B7
nom:
7356
rdg:
7359
diff:
 +3
B8
nom:
7250
rdg:
7258
diff:
 +8
B9
nom:
7226
rdg:
7232
diff:
 +6
B10
nom:
7156
rdg:
7159
diff:
 +3
B11
nom:
7137
rdg:
7143
diff:
 +6
B12
nom:
7149
rdg:
7153
diff:
 +4
C7
nom:
7451
rdg:
7461
diff:
+10
C8
nom:
7341
rdg:
7352
diff:
+11
C9
nom:
7314
rdg:
7325
diff:
+11
C10
nom:
7236
rdg:
7246
diff:
+10
C11
nom:
7215
rdg:
7227
diff:
+12
C12
nom:
7207
rdg:
7215
diff:
 +8

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (0) of the deviations of all measurements from their nominal values.

No issues were found