Review measurement

2025-01-01 15:36

Advance Iota 30 (2014)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5
nom:
7895
rdg:
7898
diff:
+3
A6
nom:
7864
rdg:
7872
diff:
+8
A7
nom:
7801
rdg:
7809
diff:
+8
A8
nom:
7810
rdg:
7820
diff:
+10

Right riser

A5
nom:
7895
rdg:
7895
diff:
+0
A6
nom:
7864
rdg:
7872
diff:
+8
A7
nom:
7801
rdg:
7807
diff:
+6
A8
nom:
7810
rdg:
7821
diff:
+11

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found