Review measurement
2025-03-17 18:08
Ozone Delta 4 MS (2020)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A15
nom:
6408
rdg:
6381
diff:
-27
A16
nom:
6335
rdg:
6306
diff:
-29
A17
nom:
6302
rdg:
6279
diff:
-23
B16
nom:
6429
rdg:
6403
diff:
-26
B17
nom:
6392
rdg:
6370
diff:
-22
B18
nom:
6356
rdg:
6336
diff:
-20
Right riser
A9
nom:
6835
rdg:
6802
diff:
-33
A10
nom:
6795
rdg:
6763
diff:
-32
A11
nom:
6716
rdg:
6689
diff:
-27
A12
nom:
6702
rdg:
6674
diff:
-28
A13
nom:
6617
rdg:
6593
diff:
-24
A14
nom:
6620
rdg:
6594
diff:
-26
A15
nom:
6408
rdg:
6384
diff:
-24
A16
nom:
6335
rdg:
6308
diff:
-27
A17
nom:
6302
rdg:
6279
diff:
-23
B16
nom:
6429
rdg:
6398
diff:
-31
B17
nom:
6392
rdg:
6368
diff:
-24
B18
nom:
6356
rdg:
6336
diff:
-20
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
Right riser
nom:
6714.17
rdg:
6685.83
diff:
-28.33
nom:
6775.54
rdg:
6757.92
diff:
-17.62
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found