Review measurement
2025-09-29 00:50
Advance OMEGA XA 5 ULS 23 (2023)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
1A9
nom:
7153
rdg:
7141
diff:
-12
1A10
nom:
7097
rdg:
7088
diff:
-9
1A11
nom:
6977
rdg:
6975
diff:
-2
1A12
nom:
6961
rdg:
6958
diff:
-3
1A13
nom:
6839
rdg:
6838
diff:
-1
1A14
nom:
6839
rdg:
6832
diff:
-7
1B9
nom:
7140
rdg:
7133
diff:
-7
1B10
nom:
7089
rdg:
7080
diff:
-9
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found