Review measurement

2026-03-22 16:38

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
7336
rdg:
7334
diff:
 -2
A16
nom:
7311
rdg:
7310
diff:
 -1
B24
nom:
7343
rdg:
7347
diff:
 +4
B25
nom:
7342
rdg:
7345
diff:
 +3

Right riser

A15
nom:
7336
rdg:
7333
diff:
 -3
A16
nom:
7311
rdg:
7312
diff:
 +1
B24
nom:
7343
rdg:
7347
diff:
 +4
B25
nom:
7342
rdg:
7350
diff:
 +8

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found