Review measurement
2024-10-29 19:04
Ozone Zeno S (2017)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B5
nom:
6665
rdg:
7146
diff:
-29
B6
nom:
6539
rdg:
7024
diff:
-25
B7
nom:
6474
rdg:
6965
diff:
-19
B8
nom:
6488
rdg:
6977
diff:
-21
C5
nom:
6738
rdg:
7216
diff:
-32
C6
nom:
6609
rdg:
7090
diff:
-29
C7
nom:
6537
rdg:
7022
diff:
-25
C8
nom:
6536
rdg:
7022
diff:
-24
Right riser
A9
nom:
6299
rdg:
6791
diff:
-28
A10
nom:
6185
rdg:
6686
diff:
-19
A11
nom:
6129
rdg:
6622
diff:
-27
A12
nom:
6080
rdg:
6581
diff:
-19
A13
nom:
6064
rdg:
6566
diff:
-18
A14
nom:
6101
rdg:
6602
diff:
-19
B12
nom:
6088
rdg:
6590
diff:
-18
B13
nom:
6096
rdg:
6596
diff:
-20
B14
nom:
6124
rdg:
6624
diff:
-20
B5
nom:
6665
rdg:
7152
diff:
-23
B6
nom:
6539
rdg:
7025
diff:
-24
B7
nom:
6474
rdg:
6964
diff:
-20
B8
nom:
6488
rdg:
6977
diff:
-21
C5
nom:
6738
rdg:
7218
diff:
-30
C6
nom:
6609
rdg:
7090
diff:
-29
C7
nom:
6537
rdg:
7020
diff:
-27
C8
nom:
6536
rdg:
7020
diff:
-26
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found