Review measurement

2025-02-03 02:37

Ozone Zeolite MS (2019)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6097
rdg:
6634
diff:
+12
A16
nom:
6044
rdg:
6578
diff:
+9
A17
nom:
6037
rdg:
6565
diff:
+3
B15
nom:
6120
rdg:
6659
diff:
+14
B16
nom:
6093
rdg:
6628
diff:
+10
B17
nom:
6080
rdg:
6616
diff:
+11

Right riser

A15
nom:
6097
rdg:
6638
diff:
+16
A16
nom:
6044
rdg:
6585
diff:
+16
A17
nom:
6037
rdg:
6575
diff:
+13
B15
nom:
6120
rdg:
6664
diff:
+19
B16
nom:
6093
rdg:
6631
diff:
+13
B17
nom:
6080
rdg:
6617
diff:
+12

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found