Review measurement

2025-06-20 12:28

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
7399
rdg:
7383
diff:
-16
B6
nom:
7262
rdg:
7248
diff:
-14
B7
nom:
7186
rdg:
7175
diff:
-11
B8
nom:
7197
rdg:
7182
diff:
-15
C5
nom:
7475
rdg:
7462
diff:
-13
C6
nom:
7336
rdg:
7322
diff:
-14
C7
nom:
7255
rdg:
7245
diff:
-10
C8
nom:
7257
rdg:
7243
diff:
-14

Right riser

B5
nom:
7399
rdg:
7381
diff:
-18
B6
nom:
7262
rdg:
7241
diff:
-21
B7
nom:
7186
rdg:
7174
diff:
-12
B8
nom:
7197
rdg:
7181
diff:
-16
C5
nom:
7475
rdg:
7457
diff:
-18
C6
nom:
7336
rdg:
7322
diff:
-14
C7
nom:
7255
rdg:
7243
diff:
-12
C8
nom:
7257
rdg:
7249
diff:
 -8

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7285.50
rdg:
7283.50
diff:
-2.00
nom:
7295.88
rdg:
7282.50
diff:
-13.38
nom:
6889.67
rdg:
6891.00
diff:
1.33
nom:
6913.33
rdg:
6902.67
diff:
-10.67

Right riser

nom:
7285.50
rdg:
7281.75
diff:
-3.75
nom:
7295.88
rdg:
7281.00
diff:
-14.88
nom:
6889.67
rdg:
6892.00
diff:
2.33
nom:
6913.33
rdg:
6905.33
diff:
-8.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found