Review measurement
2025-06-20 12:28
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B5
nom:
7399
rdg:
7381
diff:
-18
B6
nom:
7262
rdg:
7241
diff:
-21
B7
nom:
7186
rdg:
7174
diff:
-12
B8
nom:
7197
rdg:
7181
diff:
-16
C5
nom:
7475
rdg:
7457
diff:
-18
C6
nom:
7336
rdg:
7322
diff:
-14
C7
nom:
7255
rdg:
7243
diff:
-12
C8
nom:
7257
rdg:
7249
diff:
-8
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7285.50
rdg:
7283.50
diff:
-2.00
nom:
7295.88
rdg:
7282.50
diff:
-13.38
nom:
6889.67
rdg:
6891.00
diff:
1.33
nom:
6913.33
rdg:
6902.67
diff:
-10.67
Right riser
nom:
7285.50
rdg:
7281.75
diff:
-3.75
nom:
7295.88
rdg:
7281.00
diff:
-14.88
nom:
6889.67
rdg:
6892.00
diff:
2.33
nom:
6913.33
rdg:
6905.33
diff:
-8.00
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found