Review measurement

2025-02-16 18:22

Ozone Zeolite 2 GT S (2023)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6585
rdg:
6557
diff:
-28
A10
nom:
6463
rdg:
6439
diff:
-24
A11
nom:
6397
rdg:
6371
diff:
-26
A12
nom:
6307
rdg:
6292
diff:
-15
A13
nom:
6288
rdg:
6270
diff:
-18
B12
nom:
6327
rdg:
6311
diff:
-16
B13
nom:
6310
rdg:
6289
diff:
-21

Right riser

A9
nom:
6585
rdg:
6558
diff:
-27
A10
nom:
6463
rdg:
6438
diff:
-25
A11
nom:
6397
rdg:
6372
diff:
-25
A12
nom:
6307
rdg:
6288
diff:
-19
A13
nom:
6288
rdg:
6266
diff:
-22
B12
nom:
6327
rdg:
6308
diff:
-19
B13
nom:
6310
rdg:
6287
diff:
-23

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found