Review measurement

2025-06-09 16:33

Ozone Zeno 2 L (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7585
rdg:
7582
diff:
 -3
A10
nom:
7451
rdg:
7449
diff:
 -2
A11
nom:
7379
rdg:
7375
diff:
 -4
A12
nom:
7335
rdg:
7320
diff:
-15
A13
nom:
7314
rdg:
7299
diff:
-15
A14
nom:
7357
rdg:
7338
diff:
-19
B12
nom:
7344
rdg:
7331
diff:
-13
B13
nom:
7352
rdg:
7336
diff:
-16
B14
nom:
7382
rdg:
7364
diff:
-18
B9
nom:
7575
rdg:
7574
diff:
 -1
B10
nom:
7467
rdg:
7468
diff:
 +1
B11
nom:
7422
rdg:
7420
diff:
 -2

Right riser

A9
nom:
7585
rdg:
7577
diff:
 -8
A10
nom:
7451
rdg:
7441
diff:
-10
A11
nom:
7379
rdg:
7371
diff:
 -8
A12
nom:
7335
rdg:
7321
diff:
-14
A13
nom:
7314
rdg:
7299
diff:
-15
A14
nom:
7357
rdg:
7340
diff:
-17
B12
nom:
7344
rdg:
7326
diff:
-18
B13
nom:
7352
rdg:
7338
diff:
-14
B14
nom:
7382
rdg:
7363
diff:
-19
B9
nom:
7575
rdg:
7576
diff:
 +1
B10
nom:
7467
rdg:
7466
diff:
 -1
B11
nom:
7422
rdg:
7383
diff:
-39

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee