Review measurement

2026-06-03 13:55

Little Cloud Spiruline II 18 (2010)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c1
nom:
5085
rdg:
5560
diff:
+475
c2
nom:
5000
rdg:
5474
diff:
+474
c3
nom:
5015
rdg:
5492
diff:
+477
c4
nom:
5020
rdg:
5494
diff:
+474
c5
nom:
5030
rdg:
5508
diff:
+478
c6
nom:
5105
rdg:
5577
diff:
+472
d1
nom:
5230
rdg:
5704
diff:
+474
d2
nom:
5170
rdg:
5637
diff:
+467
d3
nom:
5170
rdg:
5641
diff:
+471
d4
nom:
5230
rdg:
5710
diff:
+480

Right riser

c1
nom:
5085
rdg:
5558
diff:
+473
c2
nom:
5000
rdg:
5470
diff:
+470
c3
nom:
5015
rdg:
5487
diff:
+472
c4
nom:
5020
rdg:
5494
diff:
+474
c5
nom:
5030
rdg:
5507
diff:
+477
c6
nom:
5105
rdg:
5574
diff:
+469
d1
nom:
5230
rdg:
5707
diff:
+477
d2
nom:
5170
rdg:
5643
diff:
+473
d3
nom:
5170
rdg:
5641
diff:
+471
d4
nom:
5230
rdg:
5702
diff:
+472

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found