Review measurement

2025-12-27 20:53

Ozone Lyght L (2024)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7159
rdg:
7152
diff:
 -7
A10
nom:
7027
rdg:
7024
diff:
 -3
A11
nom:
6952
rdg:
6946
diff:
 -6
A12
nom:
6872
rdg:
6864
diff:
 -8
A13
nom:
6864
rdg:
6854
diff:
-10
B12
nom:
6893
rdg:
6905
diff:
+12
B13
nom:
6892
rdg:
6906
diff:
+14

Right riser

A9
nom:
7159
rdg:
7153
diff:
 -6
A10
nom:
7027
rdg:
7024
diff:
 -3
A11
nom:
6952
rdg:
6948
diff:
 -4
A12
nom:
6872
rdg:
6865
diff:
 -7
A13
nom:
6864
rdg:
6860
diff:
 -4
B12
nom:
6893
rdg:
6884
diff:
 -9
B13
nom:
6892
rdg:
6883
diff:
 -9

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7652.25
rdg:
7641.63
diff:
-10.63
nom:
7666.25
rdg:
7667.13
diff:
0.88

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-3) of the deviations of all measurements from their nominal values.

No issues were found