Review measurement

2026-09-08 17:02

Ozone Enzo 3 L (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
7604
rdg:
7598
diff:
 -6
A16
nom:
7578
rdg:
7574
diff:
 -4
B24
nom:
7612
rdg:
7613
diff:
 +1
B25
nom:
7611
rdg:
7617
diff:
 +6

Right riser

A15
nom:
7604
rdg:
7603
diff:
 -1
A16
nom:
7578
rdg:
7581
diff:
 +3
B24
nom:
7612
rdg:
7615
diff:
 +3
B25
nom:
7611
rdg:
7616
diff:
 +5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (13) of the deviations of all measurements from their nominal values.

No issues were found