Review measurement

2024-10-08 17:47

Advance Omega Xalps 3 23 (2019)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1C9
nom:
7243
rdg:
7276
diff:
+33
1C10
nom:
7179
rdg:
7210
diff:
+31
1C11
nom:
7046
rdg:
7083
diff:
+37
1C12
nom:
7020
rdg:
7062
diff:
+42
1C13
nom:
6927
rdg:
6966
diff:
+39
1C14
nom:
6911
rdg:
6951
diff:
+40

Right riser

1C9
nom:
7243
rdg:
7282
diff:
+39
1C10
nom:
7179
rdg:
7217
diff:
+38
1C11
nom:
7046
rdg:
7083
diff:
+37
1C12
nom:
7020
rdg:
7059
diff:
+39
1C13
nom:
6927
rdg:
6968
diff:
+41
1C14
nom:
6911
rdg:
6951
diff:
+40

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found