Review measurement
2024-02-22 00:03
Ozone Enzo 3 S (2017)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A5a
nom:
7817
rdg:
7857
diff:
+40
A6a
nom:
7675
rdg:
7713
diff:
+38
A7a
nom:
7607
rdg:
7646
diff:
+39
A8a
nom:
7634
rdg:
7676
diff:
+42
A5b
nom:
7801
rdg:
7845
diff:
+44
A6b
nom:
7659
rdg:
7700
diff:
+41
A7b
nom:
7593
rdg:
7631
diff:
+38
A8b
nom:
7622
rdg:
7662
diff:
+40
Right riser
B17
nom:
7433
rdg:
7469
diff:
+36
B18
nom:
7372
rdg:
7414
diff:
+42
B19
nom:
7354
rdg:
7395
diff:
+41
B20
nom:
7283
rdg:
7328
diff:
+45
B21
nom:
7286
rdg:
7327
diff:
+41
B22
nom:
7243
rdg:
7281
diff:
+38
B23
nom:
7251
rdg:
7286
diff:
+35
A5a
nom:
7817
rdg:
7854
diff:
+37
A6a
nom:
7675
rdg:
7714
diff:
+39
A7a
nom:
7607
rdg:
7646
diff:
+39
A8a
nom:
7634
rdg:
7668
diff:
+34
A5b
nom:
7801
rdg:
7843
diff:
+42
A6b
nom:
7659
rdg:
7704
diff:
+45
A7b
nom:
7593
rdg:
7634
diff:
+41
A8b
nom:
7622
rdg:
7658
diff:
+36
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found