Review measurement
2024-07-28 09:39
Ozone Photon S (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A5a
nom:
6809
rdg:
6827
diff:
+18
A6a
nom:
6678
rdg:
6694
diff:
+16
A7a
nom:
6612
rdg:
6623
diff:
+11
A8a
nom:
6623
rdg:
6636
diff:
+13
A5b
nom:
6798
rdg:
6820
diff:
+22
A6b
nom:
6668
rdg:
6687
diff:
+19
A7b
nom:
6605
rdg:
6620
diff:
+15
A8b
nom:
6619
rdg:
6634
diff:
+15
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found