Review measurement
2025-01-29 15:22
Ozone Rush 5 ML (2018)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
C5
nom:
7135
rdg:
7111
diff:
-24
C6
nom:
7082
rdg:
7061
diff:
-21
C7
nom:
7000
rdg:
6978
diff:
-22
C8
nom:
7009
rdg:
6986
diff:
-23
D5
nom:
7194
rdg:
7174
diff:
-20
D6
nom:
7137
rdg:
7116
diff:
-21
D7
nom:
7047
rdg:
7025
diff:
-22
D8
nom:
7049
rdg:
7028
diff:
-21
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
6771.50
rdg:
6743.33
diff:
-28.17
nom:
6713.17
rdg:
6688.17
diff:
-25.00
nom:
6760.50
rdg:
6747.67
diff:
-12.83
Right riser
nom:
7040.00
rdg:
7021.75
diff:
-18.25
nom:
6973.75
rdg:
6945.00
diff:
-28.75
nom:
7081.63
rdg:
7059.88
diff:
-21.75
nom:
6771.50
rdg:
6749.67
diff:
-21.83
nom:
6713.17
rdg:
6682.17
diff:
-31.00
nom:
6760.50
rdg:
6742.83
diff:
-17.67
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found