Review measurement

2024-02-17 11:26

Ozone Zeolite GT S (2019)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

C5
nom:
6502
rdg:
7035
diff:
+13
C6
nom:
6473
rdg:
7004
diff:
+11
C7
nom:
6405
rdg:
6934
diff:
+9
C8
nom:
6403
rdg:
6928
diff:
+5
D5
nom:
6571
rdg:
7104
diff:
+13
D6
nom:
6535
rdg:
7073
diff:
+18
D7
nom:
6469
rdg:
6997
diff:
+8
D8
nom:
6463
rdg:
6994
diff:
+11
A9
nom:
6286
rdg:
6824
diff:
+13
A10
nom:
6239
rdg:
6776
diff:
+12
A11
nom:
6152
rdg:
6684
diff:
+7
A12
nom:
6147
rdg:
6680
diff:
+8
A13
nom:
6095
rdg:
6622
diff:
+2
A14
nom:
6088
rdg:
6613
diff:
+0

Right riser

C5
nom:
6502
rdg:
7029
diff:
+7
C6
nom:
6473
rdg:
7004
diff:
+11
C7
nom:
6405
rdg:
6930
diff:
+5
C8
nom:
6403
rdg:
6929
diff:
+6
D5
nom:
6571
rdg:
7105
diff:
+14
D6
nom:
6535
rdg:
7068
diff:
+13
D7
nom:
6469
rdg:
6995
diff:
+6
D8
nom:
6463
rdg:
6992
diff:
+9
A9
nom:
6286
rdg:
6820
diff:
+9
A10
nom:
6239
rdg:
6775
diff:
+11
A11
nom:
6152
rdg:
6685
diff:
+8
A12
nom:
6147
rdg:
6680
diff:
+8
A13
nom:
6095
rdg:
6622
diff:
+2
A14
nom:
6088
rdg:
6616
diff:
+3

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found