Review measurement

2026-07-11 09:56

Ozone Zeolite 2 GT MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6837
rdg:
6803
diff:
-34
A10
nom:
6709
rdg:
6680
diff:
-29
A11
nom:
6640
rdg:
6610
diff:
-30
A12
nom:
6545
rdg:
6523
diff:
-22
A13
nom:
6525
rdg:
6506
diff:
-19
B12
nom:
6566
rdg:
6544
diff:
-22
B13
nom:
6549
rdg:
6527
diff:
-22

Right riser

A9
nom:
6837
rdg:
6799
diff:
-38
A10
nom:
6709
rdg:
6676
diff:
-33
A11
nom:
6640
rdg:
6608
diff:
-32
A12
nom:
6545
rdg:
6521
diff:
-24
A13
nom:
6525
rdg:
6503
diff:
-22
B12
nom:
6566
rdg:
6544
diff:
-22
B13
nom:
6549
rdg:
6526
diff:
-23

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7313.63
rdg:
7267.63
diff:
-46.00
nom:
7314.13
rdg:
7283.00
diff:
-31.13
nom:
7080.50
rdg:
7037.00
diff:
-43.50
nom:
7098.13
rdg:
7067.38
diff:
-30.75

Right riser

nom:
7313.63
rdg:
7272.25
diff:
-41.38
nom:
7314.13
rdg:
7286.00
diff:
-28.13

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-32) of the deviations of all measurements from their nominal values.

No issues were found