Review measurement
2026-01-10 10:27
Ozone Alpina 4 ML (2020)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7024
rdg:
6961
diff:
-63
A10
nom:
6985
rdg:
6930
diff:
-55
A11
nom:
6900
rdg:
6846
diff:
-54
A12
nom:
6885
rdg:
6832
diff:
-53
A13
nom:
6797
rdg:
6747
diff:
-50
A14
nom:
6800
rdg:
6751
diff:
-49
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7417.50
rdg:
7371.75
diff:
-45.75
nom:
7349.25
rdg:
7304.75
diff:
-44.50
nom:
7517.20
rdg:
7458.90
diff:
-58.30
nom:
7222.25
rdg:
7180.75
diff:
-41.50
nom:
7170.00
rdg:
7118.00
diff:
-52.00
nom:
7323.60
rdg:
7271.30
diff:
-52.30
Right riser
nom:
7222.25
rdg:
7177.50
diff:
-44.75
nom:
7170.00
rdg:
7113.75
diff:
-56.25
nom:
7323.60
rdg:
7272.20
diff:
-51.40
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found