Review measurement

2025-08-20 22:17

Ozone Enzo 3 M (2017)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

Right riser

avg change:
2.83
std dev:
1.59
B1
dev:
-0.8
B2
dev:
-0.8
B3
dev:
+0.2
B4
dev:
-0.8
B5
dev:
-1.8
B6
dev:
+0.2
B7
dev:
+2.2
B8
dev:
+2.2
C1
dev:
+2.2
C2
dev:
+1.2
C3
dev:
-1.8
C4
dev:
-1.8

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
8319
rdg:
8328
diff:
 +9
A2a
nom:
8200
rdg:
8208
diff:
 +8
A3a
nom:
8168
rdg:
8171
diff:
 +3
A4a
nom:
8225
rdg:
8231
diff:
 +6
A1b
nom:
8299
rdg:
8311
diff:
+12
A2b
nom:
8179
rdg:
8187
diff:
 +8
A3b
nom:
8148
rdg:
8154
diff:
 +6
A4b
nom:
8207
rdg:
8216
diff:
 +9

Right riser

A1a
nom:
8319
rdg:
8334
diff:
+15
A2a
nom:
8200
rdg:
8214
diff:
+14
A3a
nom:
8168
rdg:
8181
diff:
+13
A4a
nom:
8225
rdg:
8234
diff:
 +9
A1b
nom:
8299
rdg:
8319
diff:
+20
A2b
nom:
8179
rdg:
8195
diff:
+16
A3b
nom:
8148
rdg:
8164
diff:
+16
A4b
nom:
8207
rdg:
8218
diff:
+11

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee