Review measurement

2026-01-15 18:47

Ozone Zeolite GT S (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5
nom:
6532
rdg:
7055
diff:
 -7
A6
nom:
6504
rdg:
7031
diff:
 -3
A7
nom:
6434
rdg:
6960
diff:
 -4
A8
nom:
6428
rdg:
6952
diff:
 -6
B5
nom:
6509
rdg:
7031
diff:
 -8
B6
nom:
6481
rdg:
7001
diff:
-10
B7
nom:
6412
rdg:
6931
diff:
-11
B8
nom:
6410
rdg:
6921
diff:
-19
A9
nom:
6286
rdg:
6797
diff:
-14
A10
nom:
6239
rdg:
6751
diff:
-13
A11
nom:
6152
rdg:
6663
diff:
-14
A12
nom:
6147
rdg:
6652
diff:
-20
A13
nom:
6095
rdg:
6610
diff:
-10
A14
nom:
6088
rdg:
6605
diff:
 -8
C5
nom:
6502
rdg:
7006
diff:
-16
C6
nom:
6473
rdg:
6976
diff:
-17
C7
nom:
6405
rdg:
6915
diff:
-10
C8
nom:
6403
rdg:
6911
diff:
-12
D5
nom:
6571
rdg:
7084
diff:
 -7
D6
nom:
6535
rdg:
7051
diff:
 -4
D7
nom:
6469
rdg:
6984
diff:
 -5
D8
nom:
6463
rdg:
6979
diff:
 -4

Right riser

A5
nom:
6532
rdg:
7058
diff:
 -4
A6
nom:
6504
rdg:
7034
diff:
 +0
A7
nom:
6434
rdg:
6969
diff:
 +5
A8
nom:
6428
rdg:
6956
diff:
 -2
B5
nom:
6509
rdg:
7039
diff:
 +0
B6
nom:
6481
rdg:
7010
diff:
 -1
B7
nom:
6412
rdg:
6943
diff:
 +1
B8
nom:
6410
rdg:
6936
diff:
 -4
A9
nom:
6286
rdg:
6795
diff:
-16
A10
nom:
6239
rdg:
6751
diff:
-13
A11
nom:
6152
rdg:
6662
diff:
-15
A12
nom:
6147
rdg:
6657
diff:
-15
A13
nom:
6095
rdg:
6610
diff:
-10
A14
nom:
6088
rdg:
6603
diff:
-10
C5
nom:
6502
rdg:
7001
diff:
-21
C6
nom:
6473
rdg:
6976
diff:
-17
C7
nom:
6405
rdg:
6912
diff:
-13
C8
nom:
6403
rdg:
6910
diff:
-13
D5
nom:
6571
rdg:
7082
diff:
 -9
D6
nom:
6535
rdg:
7046
diff:
 -9
D7
nom:
6469
rdg:
6985
diff:
 -4
D8
nom:
6463
rdg:
6979
diff:
 -4

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6993.75
rdg:
6993.13
diff:
-0.63
nom:
6997.63
rdg:
6986.38
diff:
-11.25

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found