Review measurement
2025-04-26 17:15
Ozone Alpina 4 ML (2020)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7024
rdg:
6972
diff:
-2
A10
nom:
6985
rdg:
6937
diff:
+2
A11
nom:
6900
rdg:
6851
diff:
+1
A12
nom:
6885
rdg:
6839
diff:
+4
A13
nom:
6797
rdg:
6756
diff:
+9
A14
nom:
6800
rdg:
6759
diff:
+9
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7417.50
rdg:
7360.75
diff:
-6.75
nom:
7349.25
rdg:
7304.75
diff:
5.50
nom:
7517.20
rdg:
7475.40
diff:
8.20
nom:
7222.25
rdg:
7169.50
diff:
-2.75
nom:
7170.00
rdg:
7120.50
diff:
0.50
nom:
7323.60
rdg:
7283.90
diff:
10.30
Right riser
nom:
7417.50
rdg:
7360.25
diff:
-7.25
nom:
7349.25
rdg:
7306.25
diff:
7.00
nom:
7517.20
rdg:
7468.30
diff:
1.10
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found