Review measurement

2025-04-26 17:15

Ozone Alpina 4 ML (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7024
rdg:
6973
diff:
 -1
A10
nom:
6985
rdg:
6938
diff:
 +3
A11
nom:
6900
rdg:
6858
diff:
 +8
A12
nom:
6885
rdg:
6840
diff:
 +5
A13
nom:
6797
rdg:
6752
diff:
 +5
A14
nom:
6800
rdg:
6757
diff:
 +7

Right riser

A9
nom:
7024
rdg:
6972
diff:
 -2
A10
nom:
6985
rdg:
6937
diff:
 +2
A11
nom:
6900
rdg:
6851
diff:
 +1
A12
nom:
6885
rdg:
6839
diff:
 +4
A13
nom:
6797
rdg:
6756
diff:
 +9
A14
nom:
6800
rdg:
6759
diff:
 +9

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7417.50
rdg:
7360.75
diff:
-56.75
nom:
7349.25
rdg:
7304.75
diff:
-44.50
nom:
7517.20
rdg:
7475.40
diff:
-41.80
nom:
7222.25
rdg:
7169.50
diff:
-52.75
nom:
7170.00
rdg:
7120.50
diff:
-49.50
nom:
7323.60
rdg:
7283.90
diff:
-39.70

Right riser

nom:
7417.50
rdg:
7360.25
diff:
-57.25
nom:
7349.25
rdg:
7306.25
diff:
-43.00
nom:
7517.20
rdg:
7468.30
diff:
-48.90

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-45) of the deviations of all measurements from their nominal values.

No issues were found