Review measurement
2024-03-29 08:21
Ozone Zeno 2 ML (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B5
nom:
7661
rdg:
7655
diff:
-6
B6
nom:
7519
rdg:
7516
diff:
-3
B7
nom:
7441
rdg:
7437
diff:
-4
B8
nom:
7451
rdg:
7444
diff:
-7
C5
nom:
7738
rdg:
7733
diff:
-5
C6
nom:
7595
rdg:
7590
diff:
-5
C7
nom:
7512
rdg:
7509
diff:
-3
C8
nom:
7512
rdg:
7504
diff:
-8
Right riser
B1
nom:
7883
rdg:
7875
diff:
-8
B2
nom:
7782
rdg:
7779
diff:
-3
B3
nom:
7746
rdg:
7744
diff:
-2
B4
nom:
7767
rdg:
7758
diff:
-9
C1
nom:
7951
rdg:
7951
diff:
+0
C2
nom:
7853
rdg:
7857
diff:
+4
C3
nom:
7814
rdg:
7818
diff:
+4
C4
nom:
7831
rdg:
7829
diff:
-2
B5
nom:
7661
rdg:
7654
diff:
-7
B6
nom:
7519
rdg:
7512
diff:
-7
B7
nom:
7441
rdg:
7434
diff:
-7
B8
nom:
7451
rdg:
7443
diff:
-8
C5
nom:
7738
rdg:
7736
diff:
-2
C6
nom:
7595
rdg:
7597
diff:
+2
C7
nom:
7512
rdg:
7513
diff:
+1
C8
nom:
7512
rdg:
7515
diff:
+3
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found