Review measurement

2025-03-13 15:04

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7651
rdg:
7657
diff:
+6
A2a
nom:
7543
rdg:
7543
diff:
+0
A3a
nom:
7506
rdg:
7509
diff:
+3
A4a
nom:
7539
rdg:
7538
diff:
-1
A1b
nom:
7636
rdg:
7632
diff:
-4
A2b
nom:
7528
rdg:
7525
diff:
-3
A3b
nom:
7492
rdg:
7488
diff:
-4
A4b
nom:
7526
rdg:
7521
diff:
-5

Right riser

A1a
nom:
7651
rdg:
7659
diff:
+8
A2a
nom:
7543
rdg:
7546
diff:
+3
A3a
nom:
7506
rdg:
7507
diff:
+1
A4a
nom:
7539
rdg:
7535
diff:
-4
A1b
nom:
7636
rdg:
7634
diff:
-2
A2b
nom:
7528
rdg:
7530
diff:
+2
A3b
nom:
7492
rdg:
7491
diff:
-1
A4b
nom:
7526
rdg:
7527
diff:
+1

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

nom:
6889.67
rdg:
6891.00
diff:
+1.33
nom:
6913.33
rdg:
6904.33
diff:
-9.00

Right riser

nom:
6889.67
rdg:
6894.67
diff:
+5.00
nom:
6913.33
rdg:
6901.00
diff:
-12.33

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found