Review measurement

2026-01-28 23:34

AirDesign Volt 5 M (2024)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7836
rdg:
7849
diff:
+13
A2a
nom:
7792
rdg:
7816
diff:
+24
A3a
nom:
7752
rdg:
7775
diff:
+23
A4a
nom:
7770
rdg:
7796
diff:
+26
A1b
nom:
7810
rdg:
7833
diff:
+23
A2b
nom:
7763
rdg:
7785
diff:
+22
A3b
nom:
7723
rdg:
7747
diff:
+24
A4b
nom:
7744
rdg:
7767
diff:
+23

Right riser

A1a
nom:
7836
rdg:
7854
diff:
+18
A2a
nom:
7792
rdg:
7812
diff:
+20
A3a
nom:
7752
rdg:
7770
diff:
+18
A4a
nom:
7770
rdg:
7786
diff:
+16
A1b
nom:
7810
rdg:
7830
diff:
+20
A2b
nom:
7763
rdg:
7782
diff:
+19
A3b
nom:
7723
rdg:
7742
diff:
+19
A4b
nom:
7744
rdg:
7763
diff:
+19

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7773.75
rdg:
7796.00
diff:
22.25
nom:
7824.42
rdg:
7835.75
diff:
11.33

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found