Review measurement

2025-11-07 04:50

AirDesign Volt 5 M (2024)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A13
nom:
7065
rdg:
7046
diff:
-19
A14
nom:
6952
rdg:
6942
diff:
-10
A15
nom:
6932
rdg:
6927
diff:
 -5
B13
nom:
7023
rdg:
7001
diff:
-22
B14
nom:
6950
rdg:
6935
diff:
-15
B15
nom:
6940
rdg:
6927
diff:
-13
C13
nom:
6978
rdg:
6964
diff:
-14
C14
nom:
7001
rdg:
6982
diff:
-19

Right riser

A13
nom:
7065
rdg:
7044
diff:
-21
A14
nom:
6952
rdg:
6942
diff:
-10
A15
nom:
6932
rdg:
6920
diff:
-12
B13
nom:
7023
rdg:
6998
diff:
-25
B14
nom:
6950
rdg:
6935
diff:
-15
B15
nom:
6940
rdg:
6927
diff:
-13
C13
nom:
6978
rdg:
6964
diff:
-14
C14
nom:
7001
rdg:
6986
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7773.75
rdg:
7787.38
diff:
13.63
nom:
7824.42
rdg:
7819.67
diff:
-4.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee