Review measurement

2025-06-06 15:15

BGD Cure ML (2016)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c1
nom:
7573
rdg:
8086
diff:
+13
c2
nom:
7441
rdg:
7962
diff:
+21
c3
nom:
7419
rdg:
7941
diff:
+22
c4
nom:
7376
rdg:
7897
diff:
+21
c5
nom:
7352
rdg:
7877
diff:
+25
c6
nom:
7433
rdg:
7950
diff:
+17

Right riser

c1
nom:
7573
rdg:
8091
diff:
+18
c2
nom:
7441
rdg:
7965
diff:
+24
c3
nom:
7419
rdg:
7953
diff:
+34
c4
nom:
7376
rdg:
7898
diff:
+22
c5
nom:
7352
rdg:
7875
diff:
+23
c6
nom:
7433
rdg:
7958
diff:
+25

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7859.00
rdg:
7893.25
diff:
34.25
nom:
7777.00
rdg:
7811.50
diff:
34.50
nom:
7932.33
rdg:
7952.17
diff:
19.83

Right riser

nom:
7377.50
rdg:
7402.50
diff:
25.00
nom:
7373.00
rdg:
7393.25
diff:
20.25
nom:
7449.25
rdg:
7459.75
diff:
10.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found