Review measurement
2024-09-06 16:45
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A1a
nom:
7651
rdg:
7650
diff:
-1
A2a
nom:
7543
rdg:
7541
diff:
-2
A3a
nom:
7506
rdg:
7507
diff:
+1
A4a
nom:
7539
rdg:
7536
diff:
-3
A1b
nom:
7636
rdg:
7637
diff:
+1
A2b
nom:
7528
rdg:
7525
diff:
-3
A3b
nom:
7492
rdg:
7491
diff:
-1
A4b
nom:
7526
rdg:
7525
diff:
-1
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found