Review measurement

2026-01-21 17:00

Skywalk Tonic 2 XS (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c6
nom:
5263
rdg:
5240
diff:
-23
c7
nom:
5235
rdg:
5213
diff:
-22
c8
nom:
5250
rdg:
5233
diff:
-17
c9
nom:
5241
rdg:
5231
diff:
-10
c10
nom:
5300
rdg:
5278
diff:
-22
d6
nom:
5341
rdg:
5316
diff:
-25
d7
nom:
5312
rdg:
5286
diff:
-26
d8
nom:
5325
rdg:
5305
diff:
-20
d9
nom:
5311
rdg:
5295
diff:
-16
d10
nom:
5359
rdg:
5338
diff:
-21
s1
nom:
4914
rdg:
4890
diff:
-24
s4
nom:
4781
rdg:
4760
diff:
-21
s2
nom:
4888
rdg:
4872
diff:
-16
s5
nom:
4769
rdg:
4751
diff:
-18
s3
nom:
4945
rdg:
4921
diff:
-24
s6
nom:
4819
rdg:
4797
diff:
-22
s7
nom:
4862
rdg:
4836
diff:
-26

Right riser

c6
nom:
5263
rdg:
5243
diff:
-20
c7
nom:
5235
rdg:
5216
diff:
-19
c8
nom:
5250
rdg:
5231
diff:
-19
c9
nom:
5241
rdg:
5226
diff:
-15
c10
nom:
5300
rdg:
5284
diff:
-16
d6
nom:
5341
rdg:
5322
diff:
-19
d7
nom:
5312
rdg:
5293
diff:
-19
d8
nom:
5325
rdg:
5301
diff:
-24
d9
nom:
5311
rdg:
5296
diff:
-15
d10
nom:
5359
rdg:
5339
diff:
-20
s1
nom:
4914
rdg:
4891
diff:
-23
s4
nom:
4781
rdg:
4760
diff:
-21
s2
nom:
4888
rdg:
4861
diff:
-27
s5
nom:
4769
rdg:
4745
diff:
-24
s3
nom:
4945
rdg:
4911
diff:
-34
s6
nom:
4819
rdg:
4797
diff:
-22
s7
nom:
4862
rdg:
4838
diff:
-24

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
5224.25
rdg:
5215.00
diff:
-9.25
nom:
5164.50
rdg:
5151.75
diff:
-12.75
nom:
5311.90
rdg:
5290.70
diff:
-21.20
nom:
5201.50
rdg:
5192.00
diff:
-9.50
nom:
5148.50
rdg:
5136.00
diff:
-12.50
nom:
5293.70
rdg:
5273.50
diff:
-20.20
nom:
5143.75
rdg:
5128.25
diff:
-15.50
nom:
5078.00
rdg:
5065.75
diff:
-12.25
nom:
5167.13
rdg:
5144.25
diff:
-22.88

Right riser

nom:
5224.25
rdg:
5216.00
diff:
-8.25
nom:
5164.50
rdg:
5151.25
diff:
-13.25
nom:
5311.90
rdg:
5291.80
diff:
-20.10

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-19) of the deviations of all measurements from their nominal values.

No issues were found