Review measurement
2024-08-15 16:30
Ozone Zeno 2 ML (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7238
rdg:
7232
diff:
-6
A10
nom:
7112
rdg:
7112
diff:
+0
A11
nom:
7043
rdg:
7040
diff:
-3
A12
nom:
6996
rdg:
6985
diff:
-11
A13
nom:
6976
rdg:
6969
diff:
-7
A14
nom:
7018
rdg:
7007
diff:
-11
B12
nom:
7005
rdg:
6993
diff:
-12
B13
nom:
7013
rdg:
7000
diff:
-13
B14
nom:
7041
rdg:
7031
diff:
-10
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found