Review measurement

2026-05-18 15:29

Ozone Zeolite MS (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6097
rdg:
6591
diff:
-31
A16
nom:
6044
rdg:
6529
diff:
-40
A17
nom:
6037
rdg:
6503
diff:
-59
B15
nom:
6120
rdg:
6615
diff:
-30
B16
nom:
6093
rdg:
6573
diff:
-45
B17
nom:
6080
rdg:
6547
diff:
-58
C5
nom:
6734
rdg:
7231
diff:
-23
C6
nom:
6703
rdg:
7199
diff:
-24
C7
nom:
6633
rdg:
7132
diff:
-21
C8
nom:
6630
rdg:
7126
diff:
-24
D5
nom:
6807
rdg:
7304
diff:
-23
D6
nom:
6770
rdg:
7262
diff:
-28
D7
nom:
6700
rdg:
7191
diff:
-29
D8
nom:
6694
rdg:
7184
diff:
-30

Right riser

A15
nom:
6097
rdg:
6591
diff:
-31
A16
nom:
6044
rdg:
6527
diff:
-42
A17
nom:
6037
rdg:
6505
diff:
-57
B15
nom:
6120
rdg:
6614
diff:
-31
B16
nom:
6093
rdg:
6576
diff:
-42
B17
nom:
6080
rdg:
6546
diff:
-59
C5
nom:
6734
rdg:
7226
diff:
-28
C6
nom:
6703
rdg:
7198
diff:
-25
C7
nom:
6633
rdg:
7132
diff:
-21
C8
nom:
6630
rdg:
7129
diff:
-21
D5
nom:
6807
rdg:
7294
diff:
-33
D6
nom:
6770
rdg:
7260
diff:
-30
D7
nom:
6700
rdg:
7195
diff:
-25
D8
nom:
6694
rdg:
7187
diff:
-27

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found