Review measurement

2024-07-03 19:27

Ozone Rush 6 XL (2021)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
5.50
std dev:
1.00
B1
dev:
+0.5
B2
dev:
-1.5
B3
dev:
+0.5
B4
dev:
+0.5
avg change:
0.13
std dev:
2.03
C5
dev:
-0.1
C6
dev:
+1.9
C7
dev:
-4.1
C8
dev:
-0.1
D5
dev:
+1.9
D6
dev:
-0.1
D7
dev:
-1.1
D8
dev:
+1.9

Right riser

avg change:
5.25
std dev:
1.50
A1
dev:
-0.8
A2
dev:
-0.8
A3
dev:
+2.3
A4
dev:
-0.8
avg change:
4.25
std dev:
1.71
A5
dev:
-1.8
A6
dev:
-0.8
A7
dev:
+2.3
A8
dev:
+0.3
avg change:
3.00
std dev:
3.16
B1
dev:
+3.0
B2
dev:
-4.0
B3
dev:
-1.0
B4
dev:
+2.0

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B1
nom:
7738
rdg:
7739
diff:
 +1
B2
nom:
7709
rdg:
7709
diff:
 +0
B3
nom:
7661
rdg:
7664
diff:
 +3
B4
nom:
7679
rdg:
7684
diff:
 +5

Right riser

B1
nom:
7738
rdg:
7741
diff:
 +3
B2
nom:
7709
rdg:
7704
diff:
 -5
B3
nom:
7661
rdg:
7664
diff:
 +3
B4
nom:
7679
rdg:
7686
diff:
 +7

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found