Review measurement
2024-12-12 11:00
Ozone Zeno 2 S (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6754
rdg:
6752
diff:
-2.00
A10
nom:
6637
rdg:
6637
diff:
0.00
A11
nom:
6574
rdg:
6572
diff:
-2.00
A12
nom:
6539
rdg:
6524
diff:
-15.00
A13
nom:
6521
rdg:
6508
diff:
-13.00
A14
nom:
6561
rdg:
6546
diff:
-15.00
B12
nom:
6547
rdg:
6536
diff:
-11.00
B13
nom:
6556
rdg:
6540
diff:
-16.00
B14
nom:
6583
rdg:
6566
diff:
-17.00
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found